∴Logic WikiA library of reasoningSearch concepts, fallacies, and cases/中文

Mars Climate Orbiter: one number, different units

火星气候轨道器:同一个数字,不同单位

A correct calculation can fail when its inputs are interpreted inconsistently.

Cited investigation report date · 1999-11-10

Original material

Short source excerpt (including title fragments); our translation

Read the English original
the failure to use metric units in the coding of a ground software file

View primary source ↗

Background: what the source reports

Open this step

NASA’s mission overview attributes the loss of Mars Climate Orbiter to a navigation error caused by a failure to convert English units to metric. The mission ended on September 23, 1999; the cited page was last updated on September 15, 2025.

Argument reconstruction · our analysis

Open this step

Reconstruction: both interfaces transmit numbers, so their values can be combined directly. Dimensions and unit conventions are missing; identical numerals need not denote identical quantities.

The report identifies the data interface

Open this step

The report states that SM_FORCES output required newton-seconds but supplied pound-force seconds, leading navigation processing to underestimate thrust effects by about 4.45. It distinguishes correct onboard computation from faulty ground modeling.

Section sources: §4, printed p. 16; §5 cause 1, pp. 17–18 ↗

Identical numerals need not denote identical quantities

Open this step

An interface contract specifies units, dimensions, and meaning as well as numeric type. Reading the numeral ten in another unit may leave software executable while changing the represented quantity.

Check input contracts, output implementation, downstream interpretation, and end-to-end behavior. This connects semantics with engineering verification without assigning individual blame from a logic label.

Carry the unit into the calculation

Open this step

The mission overview and investigation have different levels of detail; the conversion exercise is original.

Independent exercise 1

An interface expects milliseconds, but a sender encodes two seconds as 2. The receiver reads two milliseconds. What is the factor error?

Show answer and reasoning

Two seconds are 2,000 milliseconds, so the interpreted duration is smaller by a factor of 1,000. Numeric type does not guarantee unit correctness; these are not mission data.

Section sources: About the Mission and Key Facts: mission ending and page update ↗

Limits of the judgment

Open this step

The mission overview gives a brief causal account, insufficient to assign individual responsibility. Our reconstruction about interfaces is a teaching explanation, not a quotation from the engineers.

Test the distinction

Open this step

Question: Is a correct conversion formula enough? Answer: Input units, interface contracts, and end-to-end outcomes must also be verified.

References

  1. Mars Climate Orbiter Mishap Investigation Board · Phase I Report ↗
    NASA Mars Climate Orbiter Mishap Investigation Board · Selected sections
    §4, printed p. 16 (PDF page 16); §5, Contributing Cause No. 1, printed pp. 17–18
    Version, terms, and access scope
  2. Mars Climate Orbiter · Mission Overview ↗
    NASA Science · Selected sections
    About the Mission; Key Facts; page update 2025-09-15, mission ended 1999-09-23
    Version, terms, and access scope